Features :
1) Multi-jet, Magnetically Drive, Screw End with Brass nut & nipples
2) Brass body & Internal parts of plastic (Corrosion proof).
3) Conform to, IS: 779:1994,IS0: 4064 Class-B standard
4) AMR Compatiable, ready to install AMR device.
5) Protection against Magnetic Tampering.
6) Horizontal Flow and Totalizer dial’s straight reading.
7) Vaccum Sealed register,dry dial protection IP68.
8) Maximum reading capacity 99999m3.
9) Working upto 45• Celsius cold water.
10) Meters shall be guaranteed to operate normally and accurately, without leakage or damage to any part at a constant working pressure of 16kg/cm2
Accuracy :
1) From minium flow rate (Qmin) Inclusive to transitional flow rate (Qt), Exclusive +- 5%
2) From transitional flow rate (Qt) Inclusive to Maximum flow rate (Qmax), Exclusive +- 2%
Working Condition
- Water temperature ≤ 45°C
- Water pressure ≤ 1MPa
- Pressure Lose < 0.1Pa
- Maximum pressure – 16bar
Head Loss Curve:
Dimensions
Type | Size (mm) | Length (mm) L | Width (mm) W | Length including nipple ± 5% | Height (mm) H | Connecting Thread D |
Multi Jet | 15 mm | 165 | 81 | 250 | 100 | 3/4″ |
Performance Data
Nominal Size DN (MM) | Minimum Reading Quantity In liters | Hydro Static Test | Maximum Flow Rate Qmax-Lts/hr.) | Terminal flow rate qn-Lts,/ hr | Transitional Flow rate Qn-lts/ hr | Minimum starting Flow Qmin-lts/ hr |
15 | 0.1 | 2.0 Mpa | 3000 | 1500 | 120 | 30 |